• Lab Dccvd CVD Vapor Deposition System with Jacket Cooling Chamber
  • Lab Dccvd CVD Vapor Deposition System with Jacket Cooling Chamber
  • Lab Dccvd CVD Vapor Deposition System with Jacket Cooling Chamber
  • Lab Dccvd CVD Vapor Deposition System with Jacket Cooling Chamber
  • Lab Dccvd CVD Vapor Deposition System with Jacket Cooling Chamber
  • Lab Dccvd CVD Vapor Deposition System with Jacket Cooling Chamber

Lab Dccvd CVD Vapor Deposition System with Jacket Cooling Chamber

After-sales Service: on-Line Service
Warranty: One Year
Application: Industry, School, Lab
Customized: Customized
Certification: CE
Structure: Portable
Gold Member Since 2023

Suppliers with verified business licenses

Henan, China
to see all verified strength labels (15)
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Company Profile
  • Packaging & Shipping
  • FAQ
  • Contact Us
Overview

Basic Info.

Model NO.
TN-DCCVD
Material
Stainless Steel
Type
Tubular Furnace
Product Name
Dccvd System
Anode temperature
600~1100c
Cathode Temperature
700~1100c
Working Voltage
600~1200V
RF Power
150W
Transport Package
Fumigated Wooden Box
Trademark
TN
Origin
China
HS Code
8401200000
Production Capacity
20 Sets Per Month

Product Description

Product Description

Lab DCCVD CVD vapor deposition system with jacket cooling chambere

Lab Dccvd CVD Vapor Deposition System with Jacket Cooling Chamber

Hot cathode direct current plasma chemical vapor deposition equipment (DCCVD) is developed on the basis of conventional cold cathode glow discharge, and is mainly used for the deposition and growth of diamond single crystal or polycrystalline film. 
1. The composition area and basic characteristics of hot cathode glow discharge
The glow discharge of the hot cathode direct current plasma chemical vapor deposition equipment can be divided into four areas along the axis of the cathode to the anode: cathode glow layer, Faraday dark zone, positive column glow plasma ball, and anode glow layer. Among them, the cathode glow layer is a thin light-emitting layer close to the cathode, where the huge wave discharge occurs, which plays an important role in the glow discharge process; the Faraday dark zone is the transition zone between the cathode zone and the positive column zone. The electrons collide in the cathode region and lose energy, and the slow electrons are not enough to cause ionization and excitation, so they present a dark area that does not emit light; the glow plasma ball in the positive column area is at the most obvious position of the glow discharge, and its width is about the cathode The anode spacing is about 4/5, and the length changes with the change of the anode and cathode spacing; compared to the bright positive column area, the anode glow layer emits slightly darker light.
Hot cathode, high gas pressure and high current density are the basic characteristics of hot cathode glow discharge which are different from conventional cold cathode glow discharge. During discharge, there is a distribution of glow intensity, color, and brightness between the electrodes, which are divided into four obvious areas. The glow discharge covers the entire cathode surface, and the discharge voltage increases with the increase of the discharge current; the cathode electron emission is combined by the thermal emission and the γ process, and the degree of bias between the two is mainly determined by the cathode temperature; the cathode drop zone is to maintain the glow The indispensable part of the light discharge, the thickness of this area is very thin, there is a high potential drop, so the field strength in this area is very high, and generate a huge wave discharge. The current density of hot cathode glow discharge is much greater than that of cold cathode glow discharge.
Product Parameters

Specifications of DCCVD system
 

Deposition chamber Stainless steel water-cooled interlayer Design the appropriate cavity size according to the electrode size to ensure that there is no discharge between the cavity wall and the electrode
Open cavity way Lift to open the cavity or open the door in front, convenient for lofting and cleaning
Observation window Set up multiple observation windows to ensure that the cathode, anode and deposition table can be observed
Vacuum system Vacuum pump Vacuum is pumped by mechanical pump, no need to configure molecular pump
Ultimate vacuum 0.1~1Pa
Pump down time 5~15min
Vent setting Ensure uniformity of pumping
Air pressure adjustment range 0.1Pa~30KPa
Release valve Can be restored to the atmosphere
Vacuum gauge High-precision vacuum gauge accurately measures the pressure value of the cavity
Gas distribution system Air source configuration 5 gas sources of hydrogen, methane, nitrogen, argon, and oxygen, with an additional one reserved for backup
Gas flow control The volume flow is controlled by MFC, and a flow meter with a suitable range is selected according to the size of the cavity. Different flow sizes will affect the pressure rise time. In general, the flow rate of hydrogen: methane: nitrogen: argon: oxygen is 40:1:1:40:1
Air intake setting Reasonable air inlet setting to ensure air inlet uniformity
Water cooling system Water cooler power The cooling power and head of the water chiller should match the heat generation of the equipment and the cooling water flow, and the temperature should be adjustable, generally set at about 20°C
Valve  The deposition chamber, cathode, and anode all need to be cooled, and a water separator needs to be installed, and manual valves are set at the inlet and outlet of each branch on the water separator.
Operating temperature The anode working temperature is 600-1100ºC, the cathode working temperature is 700-1100ºC
Power Operating Voltage 600~1200V, adjustable output voltage
Working current 6~15A
Control System 1) Gas flow control;
2) Electrode lifting control, real-time display of cathode and anode distance, control accuracy 1mm;
3) Monitoring and display of cathode, anode and substrate temperature;
4) Some functions can be adjusted manually, such as air pressure;
5) Fault alarm to prevent misoperation;
Electrode  1) The anode diameter is 60mm, and the material is copper
2) The diameter of the cathode is 80~100mm, and the material is molybdenum. After long-term use, carbon is easy to deposit on the surface of the cathode and the discharge is unstable. Therefore, it needs to be designed as a replaceable structure;
3) The distance between the cathode and anode is adjustable, the range is 10~60mm, the distance is displayed in real time, and the adjustment accuracy is 1mm;
4) The edges of the cathode and anode can be rounded to prevent edge discharge;
5) The anode can be negatively biased, and the bias voltage range is 0~400V;
6) The edge of the electrode is insulated to prevent edge discharge;
 

 

Detailed Photos

1. WE have CVD/PECVD machine with gas supply system+vacuum system+tube furnace + plasma generator.

2. Tube furnace (temperature) :1200C, 1400C, 1600C, customized temperature is avaliable.

3. Tube furnace (heating zone) :single zone, dual zone, triple zone, customized No. of heating zone is avaliable.

4. Tube Material: quartz, corundum, alloy, and other material of tube is customizable.

5. Tube with different diameter and length is customizable.

6. Plasma generator: 100W, 150W, 300W, 500W, 1000W, and other power of plasma generator is customizable.

7. Flowmeter: 1~3 or multi channel flow meter is optional based on your process.

Lab Dccvd CVD Vapor Deposition System with Jacket Cooling Chamber

DCCVD system


Lab Dccvd CVD Vapor Deposition System with Jacket Cooling Chamber
Lab Dccvd CVD Vapor Deposition System with Jacket Cooling Chamber

CVD-- tube furnace with 1200C single heating zone 

Lab Dccvd CVD Vapor Deposition System with Jacket Cooling ChamberCVD / PECVD-- tube furnace with 1200C triple heating zone 

Lab Dccvd CVD Vapor Deposition System with Jacket Cooling ChamberPECVD-- roll- to- roll
Lab Dccvd CVD Vapor Deposition System with Jacket Cooling ChamberPECVD-- rotary type

 

Other machines:
Lab Dccvd CVD Vapor Deposition System with Jacket Cooling Chamber

Company Profile

Lab Dccvd CVD Vapor Deposition System with Jacket Cooling ChamberLab Dccvd CVD Vapor Deposition System with Jacket Cooling Chamber

Packaging & Shipping

We can ship the CVD, PECVD machine by sea, by air, by land and by Express, also we can arrange shipment according to your requirements.
Lab Dccvd CVD Vapor Deposition System with Jacket Cooling Chamber

FAQ

Q. Are you manufacturer or trading company?
A. We are professional manufacturer of  laboratory instruments, We have professional R&D team and workshop, which can promise the qulaity and after-sale service. 

Q. How's your warranty?
A. Our warranty is 12 months, and provide lifetime maintenance. We provide 24 hours on-line service.

Q. How long is your delivery time? If I want to customize the instrument, how long does it take?
A. 5-10 days----in store. Customzied products---It usually takes 30-60 days depending on your requirements.

Q. Power supply and plug?
A. We can provide products accroding to your local voltage and plug standard.

Q. How to pay?
A. T T, L / C, D / P, etc.

Q. How is the package of goods? Delivery methods?
A. Standard export fumigation sign wooden box packaging or as your requirements.

Contact Us

SHALL WE DISCUSS YOUR PROJECT?

Please get in touch and we can collaborate to get you the answers and solutions you need.
How can we help you achieve your goals? What technical obstacles can our engineering team help you overcome? Please press the 'Get in Touch' button to get in contact with us, we'd be excited to hear about your research and help you in any way we can.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory
Main Products
Evaporation Coater; Film Coater
Number of Employees
13